Westech Korea Port Devices Driver



Driver

  1. South Korea Port
  2. Westech Korea Port Devices Driver License
  3. Westech Korea Port Devices Driver Ed
  4. Westech Korea Port Devices Driver Jobs
Category:
Westech korea port devices drivers

Easily find drivers, software, and documentation for a specific product. Product FAQs Search our Product FAQ knowledge base to find answers to your product-related questions. The NPort® 5600-8-DT device servers come with two Ethernet ports that can be used as Ethernet switch ports. Connect one port to the network or server, and the other port to another Ethernet device. The dual Ethernet ports eliminate the need to connect each device to a separate Ethernet switch, reducing wiring costs.

E200_Driver3.59 MB2020-11-05download
All Cutter driver (except i-Craft)_USB_V2.21-0311.2MB2020-05-26download
All Cutter driver (except i-Craft)_ETH_V2.21-0311.2MB2020-05-26download
All Cutter driver (except i-Craft)_COM_V2.21-0311.2MB2020-05-26download
Cutter_Korean_Jaguar_driver_ETH_V1.06-01(South Korea Only)10.2MB2020-05-26download
Cutter_Korean_Jaguar_driver_COMUSB_V1.06-01(South Korea Only)10.2MB2020-05-26download
Cutter_Plotter i-Craft driver_v1.07-019.54MB2020-05-26download
S400_Driver5.70MB2020-05-26download
X500III_Driver13.4MB2020-05-22download
X380RX_Driver3.67MB2020-05-22download

Biomini is the USB fingerprint reader used for biometric enrollment.

Supported devices in BioStar 2 are shown in the link below:

  1. Pro-face by Schneider-Electric website for touch display, industrial computer, hmi, ipc, operator device, touch interface, monitor.
  2. Support Center How can we help you? Welcome to the Blackmagic Design support center. Here you will find the latest software updates, support notes, instruction manuals and all kinds of helpful information.


Biomini agent / USB Agent needs to be installed in the client PC in order to recognize the device in BioStar 2.

You can download the program from Setting > Usb Agent of BioStar 2 web client

Download technisat driver.

Terminology

Up to BioStar 2.3, the program was called Biomini Agent because only biomini was used with the program.

However in BioStar 2.4 the program's name changed to USB Agent because it now supports DE-620 as well.



Configuration


Note: Although you have a option to check 'run on Windows startup', the USB Agent will not run automatically (up to BioStar 2.5) because of a bug.

You will have to run USB Agent manually in the Windows start menu when you restart your PC.

[This feature does not work up to BioStar 2.5]


1. Install the latest driver Download usb driver.

First check that the latest fingerprint driver is installed (version 2.2)

Direct download link:


Note: unplug the Biomini when you are installing the driver.

The driver can also be found at Suprema ID homepage : download center.


Devices

Login is required in accordance with your account.





2. Check Device manager

Open device manager and check that Suprema Fingerprint Scanner is detected properly.


3. Check USB Agent Certification

USB Agent is running. You can search it in the Windows start menu.


Once the program is running right click on the USB Agent icon on the system tray and click Setup.


Click Enroll Certificates and click Yes when a Security Warning popup appears to enroll the certificate.


Restart the service by clicking Stop and then Start


4. Check the BioStar 2 Device menu

If all settings are configured properly, the device should appear as a USB device on the Device menu.



Troubleshooting


1. Check if the USB Agent port is being used by another service

You currently (BioStar 2.5) cannot change the default port use of the USB Device Agent of 8081 and 8082 because of a UI bug.

Check that port 8081 and 8082 is not being used by another service.

Refer to the guide below:

If another service is using port 8081 and 8082 then service will crash or 'Started' will be not shown when you click Start.
Remove the other service that is using the same ports.


Or you can change the Biomini Agent port in BioStar 2.6 as desired and above as shown below:


If you must change the USB Agent port in BioStar 2.5 or below refer to the guide below:


2. Change Access privileges
If you're getting the error below every time when scanning the fingerprint with Biomini, it is likely that USB Agent is being run with insufficient privileges.


In that case stop the process first in Task Manager.

In BioStar 2.3 or below the service will appear as Biomini-Agent.exe *32


In BioStar 2.4 and above the service will appear as usb-agent.exe *32


Search the Biomini Agent / USB Agent in Windows Start menu and select the Properties menu after a right click.


Check Run this program and an administrator on the compatibility tab and click OK


Run Biomini Agent / USB Agent again.




3. Check the API

If you are using a proxy server, you will have to add the localhost as an exception.


You can check if the localhost is working correctly by trying to access the URL below:


localhost:[webserver port]/api/device

The image above shows that the connection is possible and working.

South Korea Port

If you get a error message like below even if BioStar 2 service is running, it means that localhost connection is blocked.



Port

4. Check the USB Agent logs Wortmann driver.

You can find the USB agent logs in the folder below:

Westech Korea Port Devices Driver License

C:Program Files (x86)USB Device Agentusb-agentlogs


Westech Korea Port Devices Driver Ed

Open the log files to see what errors are appearing.

Westech Korea Port Devices Driver Jobs

Provide the log file to the technical support team when requested.